OIL-FIRED FURNACE SPECIFICATIONS - THERMOPRIDE

MODEL NO.10

OL2-564

OL5-85

OL11-105

OL16-125

OL20-151

OL33-2003

OL37-2503

OL39-3203

BTU PER HR. INPUT

70,000

106,250

126,000

156,250

185,000

250,000

312,500

400,000

BTU PER HR. OUTPUT AT BONNET7

56,000

85,000

101,000

125,000

151,000

200,000

250,000

320,000

HEIGHT OF CASING

34-3/4"

43-1/4"

46-1/2"

46-1/2"

50-1/2"

60-3/4"

67-3/4"

67-3/4"

WIDTH OF CASING

19"

25"

25"

27"

27"

34"

38"

38"

DEPTH OF CASING

48"

50-1/4"

54-1/2"

58-1/2"

58-1/2"

72"

85-1/2"

85-1/2"

WARM AIR OUTLET2

17"X17"

20"X20"

20"X20"

22"X22"

22"X22"

28"X28"

32"X32"

32"X32"

RETURN AIR INLET2

17"X17"

20"X14"

20"X16"

22"X18"

22"X18"

28"X24"

32"X28"

32"X28"

DIA. OF FLUE OUTLET

5"

6"

6"

7"

7"

9"

9"

9"

FLOOR-CENTER OF FLUE

29-1/4"

36"

38-1/2"

40"

44"

51-3/4"

59"

59"

NOZZLE

.55

.75

.90

1.25

1.35

2.00

2.50

3.00

NOZZLE Shipped

.50
70 H

.75
80 H

.90
80 H

1.10
80H

1.35
80S

1.75
80S

2.25
80S

2.75
80S

NO. AND SIZE OF PERMANENT FILTERS

ONE 16"X20"

ONE 20"X20"

ONE 20"x25"

TWO 14"x25"

TWO 14"x25"

11TWO 2"X20"X25"

11FOUR 2"X16"X20"

11FOUR 2"X16"X20"

APPROX. EFFECTIVE PERMANENT FILTERS

3038.4 SQ. IN.

4850 SQ. IN.

5500 SQ. IN.

7400 SQ. IN.

7525 SQ. IN.

12,000 SQ. IN.

16,000 SQ. IN.

16,000 SQ. IN.

APPROX. SHIPPING WT.

315 LBS.

410 LBS.

500 LBS.

560 LBS.

600 LBS.

1025 LBS.

1120 LBS.

1150 LBS.

SEASONAL EFFICIENCY8

82.8%

82.0%

81.6%

80.0%

81.1%

N/A9

N/A9

N/A9

SEASONAL EFFICIENCY WITH VENT DAMPER

85.6%

84.0%

84.6%

83.0%

83.6%

N/A9

N/A9

N/A9